•Temperature•Humidity•Dew Point•Two-state Inputs•CounterMobile Data loggers measure physical quantities such as temperature, dew point, humidity and monitor also two-state signals or count pulses. The measuring intervalcan be set up from 1s to 24h. The measured value is shown on LCD display as well as MIN / MAX value.
Alarm indication
•Exceeding of alarm limits on the channel•Device failure•Battery condition•Memory occupancy•External power failureFor each measurement channel can be set upper and lower limits. In case the limits
are exceeded these alarm is indicated on the display, visually by LED or acoustically. Built-in GSM modem allows to send alarm via SMS as text message. Users can be also informed about device failure, battery and memory state or external power failure. The device also supports Latched alarms - every alarm occurring in the device remains active until some operator’s action, irrespective of the measurement values (until the time of manual cancel).
record
•Non-cyclic record mode•Cyclic record mode (FIFO)•Recording continuously•Recording at the alarm timeRecording can be performed continuously or at the alarm time only. Measured data can be stored in memory at intervals from 1s to 24h. Logging mode can be adjusted as non-cyclic, when logging stops after filling the memory or cyclic, when the oldest recorded valuesare overwritten by new ones after memory is full (first in first out). Up to 500 000 values can be stored in memory.
dATA TRANSMITTING VIA GSM
•Alarm indication via SMS as texts•Keep alive texts•Data collecting to Comet cloud and software via GSMBuilt-in battery operated GSM modem allows alarm indication and data transmitting. Data can be sent in the shortest interval of 5min to Comet database software or Comet cloud thru data network. For saving battery live there is a function of data buffering to keep GSM modem in the sleeping mode for longer time. Users can also set up keep alive texts which periodically inform of current state.
EXTERNAL TEMPERATURE PROBES
Temperature probes on the cable are designed to measure the temperature in specific applications. Probes are supplied in lengths of 1, 2, 5 and 10 meters. Probes are manufactured in accuracy of class A, unless stated otherwise.
External temperature
/humidity probes
Sensor covers for
external probes
Fast accurate air probe with fast response time without protection against moisture.
Universal temperature watertight probe with IP68 for long-term monitoring of temperature in liquids.
Brass probe for surface temperature measurements. Probe is not resistant to moisture.
Hand-held pointed tip probe for food industry with teflon handle and silicon cable.
•Temperature•Humidity•Dew Point•Two-state Inputs•CounterMobile Data loggers measure physical quantities such as temperature, dew point, humidity and monitor also two-state signals or count pulses. The measuring intervalcan be set up from 1s to 24h. The measured value is shown on LCD display as well as MIN / MAX value.
Alarm indication
•Exceeding of alarm limits on the channel•Device failure•Battery condition•Memory occupancy•External power failureFor each measurement channel can be set upper and lower limits. In case the limits are exceeded these alarm is indicated on the display, visually by LED or acoustically. Built-in GSM modem allows to send alarm via SMS as text message. Users can be also informed about device failure, battery and memory state or external power failure. The device also supports Latched alarms - every alarm occurring in the device remains active until some operator’s action, irrespective of the measurement values (until the time of manual cancel).
record
•Non-cyclic record mode•Cyclic record mode (FIFO)•Recording continuously•Recording at the alarm timeRecording can be performed continuously or at the alarm time only. Measured data can be stored in memory at intervals from 1s to 24h. Logging mode can be adjusted as non-cyclic, when logging stops after filling the memory or cyclic, when the oldest recorded valuesare overwritten by new ones after memory is full (first in first out). Up to 500 000 values can be stored in memory.
dATA TRANSMITTING VIA
GSM
•Alarm indication via SMS as texts•Keep alive texts•Data collecting to Comet cloud and software via GSMBuilt-in battery operated GSM modem allows alarm indication and data transmitting. Data can be sent in the shortest interval of 5min to Comet database software or Comet cloud thru data network. For saving battery live there is a function of data buffering to keep GSM modem in the sleeping mode for longer time. Users can also set up keep alive texts which periodically inform of current state.
EXTERNAL TEMPERATURE
PROBES
Temperature probes on the cable are designed to measure the temperature in specific applications. Probes are supplied in lengths of 1, 2, 5 and 10 meters. Probes are manufactured in accuracy of class A, unless stated otherwise.
External temperature
/humidity probes
Fast accurate air probe with fast response time without protection against moisture.
POWER SUPPLY AND usb-c
CABLE INCLUDED
Universal temperature watertight probe with IP68 for long-term monitoring of temperature in liquids.
Hand-held pointed tip probe for food industry with teflon handle and silicon cable.
Brass probe for surface temperature measurements. Probe is not resistant to moisture.